EURAMET Thermophysical Quantities Database
Records found: 132
Enthalpy of transition
Method/Apparatus: | DSC - dynamic scanning calorimetry |
Ranges: | RT … 1500 |
Samples: | solids, melts, liquids Ø: < 5 h: < 1 |
Institute/Delegate: | ZAE Bayern |
Contact: | Michael Brütting |
Email: | michael.bruetting@zae-bayern.de |
Website: | www.zae-bayern.de |
Enthalpy of transition
Method/Apparatus: | DSC - dynamic scanning calorimetry |
Ranges: | -90 … 500 |
Samples: | solids, melts, liquids Ø: < 4.5 h: < 1 |
Institute/Delegate: | ZAE Bayern |
Contact: | Michael Brütting |
Email: | michael.bruetting@zae-bayern.de |
Website: | www.zae-bayern.de |
Enthalpy of transition
Method/Apparatus: | Macro - DSC |
Ranges: | 15 .. 50 |
Samples: | solids, melts, liquids < 100 x 100 h: < 20 |
Institute/Delegate: | ZAE Bayern |
Contact: | Michael Brütting |
Email: | michael.bruetting@zae-bayern.de |
Website: | www.zae-bayern.de |
Enthalpy of transition
Method/Apparatus: | Macro - T-History |
Ranges: | 15 .. 50 |
Samples: | solids, melts, liquids < 100 x 100 h: < 20 |
Institute/Delegate: | ZAE Bayern |
Contact: | Michael Brütting |
Email: | michael.bruetting@zae-bayern.de |
Website: | www.zae-bayern.de |
Enthalpy of transition
Method/Apparatus: | HFM Calorimetry |
Ranges: | 15 .. 50 |
Samples: | solids, melts, liquids < 200 x 200 h: < 20 |
Institute/Delegate: | ZAE Bayern |
Contact: | Michael Brütting |
Email: | michael.bruetting@zae-bayern.de |
Website: | www.zae-bayern.de |
Enthalpy of transition
Method/Apparatus: | simultaneous DSC (DTA) |
Ranges: | RT … 1500 |
Samples: | solids, powders, pastes, melts, liquids Ø: 7 h: 7 m: 500mg |
Institute/Delegate: | ZAE Bayern |
Contact: | Michael Brütting |
Email: | michael.bruetting@zae-bayern.de |
Website: | www.zae-bayern.de |
Enthalpy of transition
Method/Apparatus: | DSC - dynamic scanning calorimetry |
Ranges: | RT … 1200 |
Samples: | solids, melts Ø: 6 thickness: 0.5 … 2 |
Institute/Delegate: | Österreichiches Gießerei-Institut |
Contact: | Dr. Erhard Kaschnitz |
Email: | erhard.kaschnitz@ogi.at |
Website: | www.ogi.at |
Enthalpy of transition
Method/Apparatus: | dynamic scanning calorimetry - DSC or differential thermal analysis - DTA / DSC 404F1, STA449C, STA449F1, STA429 |
Ranges: | -160 … 2400 |
Samples: | solids, powders, melts, liquids Ø: 5 h: < 10 |
Institute/Delegate: | Fraunhofer IKTS Dresden |
Contact: | Dr. Tim Gestrich |
Email: | Tim.Gestrich@ikts.fraunhofer.de |
Website: | www.ikts.fraunhofer.de |
Enthalpy of transition
Method/Apparatus: | DSC |
Ranges: | -45 … 90° |
Samples: | liquids, solids |
Institute/Delegate: | ILK Dresden gGmbH |
Contact: | Dr. Steffen Feja |
Email: | steffen.feja@ilkdresden.de |
Website: | www.ilkdresden.de |
Enthalpy of transition
Method/Apparatus: | DSC |
Ranges: | -180 … 750° |
Samples: | liquids, solids |
Institute/Delegate: | ILK Dresden gGmbH |
Contact: | Dr. Steffen Feja |
Email: | steffen.feja@ilkdresden.de |
Website: | www.ilkdresden.de |
Enthalpy of transition
Method/Apparatus: | µDSC VIIdynamic scanningcalorimetry |
Ranges: | -45…90 |
Samples: | liquids, solids |
Institute/Delegate: | ILK Dresden gGmbH |
Contact: | Dr. Steffen Feja |
Email: | steffen.feja@ilkdresden.de |
Website: | www.ilkdresden.de |
Enthalpy of transition
Method/Apparatus: | Q 200dynamic scanningcalorimetry |
Ranges: | -180…750 |
Samples: | liquids, solids |
Institute/Delegate: | ILK Dresden gGmbH |
Contact: | Dr. Steffen Feja |
Email: | steffen.feja@ilkdresden.de |
Website: | www.ilkdresden.de |
Enthalpy of transition
Method/Apparatus: | DSC - dynamic scanning calorimetry |
Ranges: | RT … 1600 |
Samples: | solids, melts Ø: <5 h: <2 |
Institute/Delegate: | Fraunhofer Institut für Werkstoffmechanik IWM |
Contact: | Dr. Dirk Helm |
Email: | dirk.helm@iwm.fraunhofer.de |
Website: | www.iwm.fraunhofer.de |
Enthalpy of transition
Method/Apparatus: | DSC - differential scanning calorimetry |
Ranges: | -180…1600 |
Samples: | solids in various dimensions, powders, pastes, liquids |
Institute/Delegate: | AIT Austrian Institute of Technology |
Contact: | DI (FH) Daniel Lager, MSc / Dr.-Ing.Wolfgang Hohenauer |
Email: | daniel.lager@ait.ac.at / wolfgang.hohenauer@ait.ac.at |
Website: | http://www.ait.ac.at/en/research-fields/thermophysics/ |
Enthalpy of transition
Method/Apparatus: | DSC - dynamic scanning calorimetry |
Ranges: | -90…500 |
Samples: | solids, powders, pastes, liquids |
Institute/Delegate: | SGL Carbon GmbH |
Contact: | Dr. Alfred Chodura |
Email: | alfred.chodura@sglgroup.com |
Website: | www.sglgroup.com |
Enthalpy of transition
Method/Apparatus: | STA; thermogravimetry TG +simultaneous DSC (DTA), FTIR, MSor only DSC |
Ranges: | 40 … 1600 or-160 …600 |
Samples: | solids, powders, pastes, liquids… |
Institute/Delegate: | thyssenkrupp Steel Europe AG |
Contact: | Dr. Diana Neubert |
Email: | diana.neubert@thyssenkrupp.com |
Website: | www.thyssenkrupp-steel.com |
Enthalpy of transition
Method/Apparatus: | dynamic scanning calorimetry / differential thermal analysis |
Ranges: | -160 … 2400 |
Samples: | solids, powders, melts, liquids Ø: 5 h: < 10 |
Institute/Delegate: | Netzsch Gerätebau |
Contact: | Dr. Jan Hanss |
Email: | jan.hanss@netzsch.com |
Website: | https://www.netzsch-thermal-analysis.com |
Enthalpy of transition
Method/Apparatus: | DSC-TG - dynamic scanningcalorimetry and thermogravimetry |
Ranges: | RT…1450,H2Ov RT..1150 |
Samples: | solids, powders, pasts: 85µl, Ø<5mm, h<3mm |
Institute/Delegate: | IAB Institut für Angewandte Bauforschung Weimar gGmbH |
Contact: | Alexander Eppner |
Email: | a.eppner@iab-weimar.de |
Website: | www.iab-weimar.de |
Enthalpy oftransition
Method/Apparatus: | DSC - dynamic scanningcalorimetry |
Ranges: | RT…1600 |
Samples: | solids and powdersØ: 4h: 1 |
Institute/Delegate: | SCHOTT AG Mainz |
Contact: | Dr. Christoph Groß |
Email: | christoph1.gross@schott.com |
Website: | www.schott.com |
Infrared optical values
Method/Apparatus: | emittance / emissivity:spectral and total,directional and hemispherical |
Ranges: | 200 … 3000 |
Samples: | solids, coatings,powders, liquids, gasesca. 20 x 20 or Æ = 20and on request |
Institute/Delegate: | ZAE Bayern |
Contact: | Dr. Jochen Manara |
Email: | jochen.manara@zae-bayern.de |
Website: | www.zae-bayern.de |
Infrared optical values
Method/Apparatus: | transmittance / transmissivity:spectral and total,directional-hemispherical |
Ranges: | 200 … 1600 |
Samples: | solids, coatings,powders, liquids, gasesca. 20 x 20 or Æ = 20and on request |
Institute/Delegate: | ZAE Bayern |
Contact: | Dr. Jochen Manara |
Email: | jochen.manara@zae-bayern.de |
Website: | www.zae-bayern.de |
Infrared optical values
Method/Apparatus: | reflectance / reflectivity:spectral and total,directional-hemispherical |
Ranges: | 0 … 200 |
Samples: | solids, coatings,powders, liquidsmin. 20 x 20 or Æ = 20and on request |
Institute/Delegate: | ZAE Bayern |
Contact: | Dr. Jochen Manara |
Email: | jochen.manara@zae-bayern.de |
Website: | www.zae-bayern.de |
Infrared optical values
Method/Apparatus: | transmittance / transmissivity:spectral and total,directional-hemispherical |
Ranges: | 0 … 200 |
Samples: | solids, coatings,powders, liquidsmin. 20 x 20 or Æ = 20and on request |
Institute/Delegate: | ZAE Bayern |
Contact: | Dr. Jochen Manara |
Email: | jochen.manara@zae-bayern.de |
Website: | www.zae-bayern.de |
Infrared optical values
Method/Apparatus: | reflectance / reflectivity:spectral and total,directional-directional |
Ranges: | -200 … +200 |
Samples: | solids, coatings,powders, liquids40 x 40 … 40 x 60and on request |
Institute/Delegate: | ZAE Bayern |
Contact: | Dr. Jochen Manara |
Email: | jochen.manara@zae-bayern.de |
Website: | www.zae-bayern.de |
Infrared optical values
Method/Apparatus: | transmittance / transmissivity:spectral and total,directional-directional |
Ranges: | -200 … +200 |
Samples: | solids, coatings,powders, liquids40 x 40 … 40 x 60and on request |
Institute/Delegate: | ZAE Bayern |
Contact: | Dr. Jochen Manara |
Email: | jochen.manara@zae-bayern.de |
Website: | www.zae-bayern.de |
Infrared optical values
Method/Apparatus: | extinction coefficient, albedo, scattering coefficient andabsorption coefficient |
Ranges: | -200 … 1600 |
Samples: | solids, coatings,powders, liquids, gasessample size on request |
Institute/Delegate: | ZAE Bayern |
Contact: | Dr. Jochen Manara |
Email: | jochen.manara@zae-bayern.de |
Website: | www.zae-bayern.de |
Infrared optical values
Method/Apparatus: | complex index of refraction and complex dielectric function |
Ranges: | -200 … 1600 |
Samples: | solids, coatings,powders, liquids, gasessample size on request |
Institute/Delegate: | ZAE Bayern |
Contact: | Dr. Jochen Manara |
Email: | jochen.manara@zae-bayern.de |
Website: | www.zae-bayern.de |
Infrared optical values
Method/Apparatus: | spectrometer,radiation thermometer(pyrometer),IR-detector and IR-camera |
Ranges: | -200 … 3000 |
Samples: | solids, coatings,powders, liquids, gases |
Institute/Delegate: | ZAE Bayern |
Contact: | Dr. Jochen Manara |
Email: | jochen.manara@zae-bayern.de |
Website: | www.zae-bayern.de |
Infrared optical values
Method/Apparatus: | black body radiator,panel radiator,fixed-point radiator and lampfor calibration issues |
Ranges: | -200 … 3000 |
Samples: | solids, coatings,powders, liquids, gases |
Institute/Delegate: | ZAE Bayern |
Contact: | Dr. Jochen Manara |
Email: | jochen.manara@zae-bayern.de |
Website: | www.zae-bayern.de |
Infrared optical values
Method/Apparatus: | directional emittance |
Ranges: | 700 … 1500 |
Samples: | solids, coatings Ø: ~ 15 thickness: ~ 4 … 6 |
Institute/Delegate: | IKE, Universität Stuttgart |
Contact: | Marc LinderDr. Rudi Kulenovic |
Email: | marc.linder@ ike.uni-stuttgart.de / rudi.kulenovic@ ike.uni-stuttgart.de |
Website: | www.ike.uni-stuttgart.de |
Infrared optical values
Method/Apparatus: | high resolution IR camera |
Ranges: | - |
Samples: | - |
Institute/Delegate: | Fraunhofer IPM |
Contact: | Jan König |
Email: | jan.koenig@ipm.fraunhofer.de |
Website: | www.ipm.fraunhofer.de |
Infrared optical values
Method/Apparatus: | FT-IR |
Ranges: | RT … 200 |
Samples: | thin films and solids |
Institute/Delegate: | Fraunhofer IPM |
Contact: | Jan König |
Email: | jan.koenig@ipm.fraunhofer.de |
Website: | www.ipm.fraunhofer.de |
Infrared optical values
Method/Apparatus: | FT-IR |
Ranges: | RT … 200 |
Samples: | thin films, powders and solids |
Institute/Delegate: | SGL Carbon GmbH |
Contact: | Dr. Alfred Chodura |
Email: | Alfred.Chodura@sglgroup.comipm.fraunhofer.de |
Website: | www.sglgroup.com |
Infrared optical values
Method/Apparatus: | FT-IR ATR, FT-IR (directional transmittance), NIR (directional transmittance) |
Ranges: | RT |
Samples: | solids, coatings, layers, powder,liquids (mind. 0.1 mL), components(up to 300 x 140 x 15*) |
Institute/Delegate: | IKV an der RWTH Aachen |
Contact: | Dipl.-Ing. (FH) Michèle Marson-Pahle |
Email: | michele.marson-pahle@ikv.rwth-aachen.de |
Website: | www.ikv-aachen.de |
Infrared optical values
Method/Apparatus: | directional spectral emissivity; |
Ranges: | -40 … 1000 |
Samples: | solids, coatingsØ: 40 … 120thickness: < 10 |
Institute/Delegate: | PTB |
Contact: | Dr. Christian Monte |
Email: | christian.monte@ptb.de |
Website: | www.ptb.de |
Infrared optical values
Method/Apparatus: | directional total emissivity; |
Ranges: | -40 … 1000 |
Samples: | solids, coatingsØ: 40 … 120thickness: < 10 |
Institute/Delegate: | PTB |
Contact: | Dr. Christian Monte |
Email: | christian.monte@ptb.de |
Website: | www.ptb.de |
Infrared optical values
Method/Apparatus: | hemispherical emissivity; |
Ranges: | -40 … 1000 |
Samples: | solids, coatingsØ: 40 … 120thickness: < 10 |
Institute/Delegate: | PTB |
Contact: | Dr. Christian Monte |
Email: | christian.monte@ptb.de |
Website: | www.ptb.de |
Infrared optical values
Method/Apparatus: | directional spectral emissivity; |
Ranges: | 800 … 1500 |
Samples: | solids Ø: 10thickness: < 5 |
Institute/Delegate: | PTB |
Contact: | Dr. Klaus Anhalt |
Email: | klaus.anhalt@ptb.de |
Website: | www.ptb.de |
Infrared optical values
Method/Apparatus: | directional-hemisphericalreflectance |
Ranges: | 23 |
Samples: | solids, coatingsØ: 5 … 40 |
Institute/Delegate: | PTB |
Contact: | Dr. Christian Monte |
Email: | christian.monte@ptb.de |
Website: | www.ptb.de |
Infrared optical values
Method/Apparatus: | directional-hemisphericaltransmittance |
Ranges: | 23 |
Samples: | solids, coatingsØ: 5 … 40 |
Institute/Delegate: | PTB |
Contact: | Dr. Christian Monte |
Email: | christian.monte@ptb.de |
Website: | www.ptb.de |
Infrared optical values
Method/Apparatus: | directional-directionalreflectance |
Ranges: | 23 |
Samples: | solids, coatingsØ: 5 … 200 |
Institute/Delegate: | PTB |
Contact: | Dr. Christian Monte |
Email: | christian.monte@ptb.de |
Website: | www.ptb.de |
Infrared optical values
Method/Apparatus: | directional-directionaltransmittance |
Ranges: | 23 |
Samples: | solids, coatingsØ: 5 … 200 |
Institute/Delegate: | PTB |
Contact: | Dr. Christian Monte |
Email: | christian.monte@ptb.de |
Website: | www.ptb.de |
Misc.
Method/Apparatus: | TGA/DTA/DSC (STA) with coupled FTIR, MS |
Ranges: | - 120 … 1600 |
Samples: | solids, liquids, powders, pastesm < 5g |
Institute/Delegate: | Austrian Institute of Technology |
Contact: | DI (FH) Daniel Lager, MSc / Dr.-Ing.Wolfgang Hohenauer |
Email: | daniel.lager@ait.ac.at / wolfgang.hohenauer@ait.ac.at |
Website: | http://www.ait.ac.at/en/research-fields/thermophysics/ |
Misc.
Method/Apparatus: | heating microscope |
Ranges: | RT … 1300 |
Samples: | solids, powders 3 x 3 x 3 |
Institute/Delegate: | ZAE Bayern |
Contact: | Michael Brütting |
Email: | michael.bruetting@zae-bayern.de |
Website: | www.zae-bayern.de |
Misc.
Method/Apparatus: | thermogravimetry TG + simultaneous DSC (DTA) |
Ranges: | RT … 1500 |
Samples: | solids, powders, pastes, melts, liquids Ø: 7 h: 7 m: 500mg |
Institute/Delegate: | ZAE Bayern |
Contact: | Michael Brütting |
Email: | michael.bruetting@zae-bayern.de |
Website: | www.zae-bayern.de |
Misc.
Method/Apparatus: | speed of sound pulse-echo-apparatus |
Ranges: | 0 … 250 |
Samples: | liquids |
Institute/Delegate: | HSU Hamburg |
Contact: | Prof. Dr. Stephan Kabelac |
Email: | kabelac@hsu-hh.de |
Website: | www.hsu-hh.de/ thermodynamik |
Misc.
Method/Apparatus: | electrical resistivity by pulse heating |
Ranges: | RT … 1500 |
Samples: | solids Ø: 4 h: 50 |
Institute/Delegate: | Östereichisches Gießerei-Institut |
Contact: | Dr. Erhard Kaschnitz |
Email: | erhard.kaschnitz@ogi.at |
Website: | www.ogi.at |
Misc.
Method/Apparatus: | thermogravimetry TG + simultaneous DSC (DTA) |
Ranges: | RT … 1500 |
Samples: | powder, pastes m: 0.1 … 10 g |
Institute/Delegate: | RHI AG TC-Leoben |
Contact: | Alois Triessnig Gerhard Urbanek |
Email: | alois.triessnig@rhi-ag.com /gerhard.urbanek@rhi-ag.com |
Website: | www.rhi-ag.com |
Misc.
Method/Apparatus: | simultaneous thermogravimetry - differential thermal analysis - evolved gas analysis with MS and FTIR, Seebeck coefficient and electrical conductivity, Benetzungsverhalten, Infiltration, Thermoschockparameter |
Ranges: | -160 … 2000 |
Samples: | solids, powders, liquids Ø: 4 … 55 h: 1 … 55 |
Institute/Delegate: | Fraunhofer IKTS Dresden |
Contact: | Dr. Tim Gestrich |
Email: | Tim.Gestrich@ikts.fraunhofer.de |
Website: | www.ikts.fraunhofer.de |
Misc.
Method/Apparatus: | Seebeck coefficient and electrical conductivity |
Ranges: | RT … 1000 |
Samples: | solids |
Institute/Delegate: | Fraunhofer IPM |
Contact: | Jan König |
Email: | jan.koenig@ipm.fraunhofer.de |
Website: | www.ipm.fraunhofer.de |
Misc.
Method/Apparatus: | Seebeck coefficient and electrical conductivity |
Ranges: | RT … 400 |
Samples: | thin films |
Institute/Delegate: | Fraunhofer IPM |
Contact: | Jan König |
Email: | jan.koenig@ipm.fraunhofer.de |
Website: | www.ipm.fraunhofer.de |
Misc.
Method/Apparatus: | Fluid-fluid miscibility Viscosity Desity Vapor pressure, etc. |
Ranges: | -60 … 90° |
Samples: | liquids |
Institute/Delegate: | ILK Dresden gGmbH |
Contact: | Dr. Steffen Feja |
Email: | steffen.feja@ilkdresden.de |
Website: | www.ilkdresden.de |
Misc.
Method/Apparatus: | Fluid-fluid miscibility, density, viscosity vapor pressure |
Ranges: | -40…90 |
Samples: | liquids |
Institute/Delegate: | ILK Dresden gGmbH |
Contact: | Dr. Steffen Feja |
Email: | steffen.feja@ilkdresden.de |
Website: | www.ilkdresden.de |
Force, temperatre, thermal expansion
Method/Apparatus: | Gleeble |
Ranges: | RT … liquefied material |
Samples: | Every conducting material Various sample sizes (sheet metal, round stock, square bar material,…) |
Institute/Delegate: | Fraunhofer Institut für Werkstoffmechanik IWM |
Contact: | Dr. Dirk Helm |
Email: | dirk.helm@iwm.fraunhofer.de |
Website: | www.iwm.fraunhofer.de |
Misc.
Method/Apparatus: | thermogravimetry (TGA), micro- and macro-TGA |
Ranges: | RT … 1000 |
Samples: | solids, powders, pastes |
Institute/Delegate: | SGL CARBON GmbH |
Contact: | Dr. Alfred Chodura |
Email: | alfred.chodura@sglgroup.com |
Website: | www.sglgroup.com |
Misc.
Method/Apparatus: | thermogravimetry (TGA) combined with evolved gas analysis by GC/MS and/or FTIR |
Ranges: | RT … 1000 |
Samples: | solids, powders, pastes |
Institute/Delegate: | SGL CARBON GmbH |
Contact: | Dr. Alfred Chodura |
Email: | alfred.chodura@sglgroup.com |
Website: | www.sglgroup.com |
Misc.
Method/Apparatus: | Viscosity |
Ranges: | RT … 250 |
Samples: | pastes, liquids |
Institute/Delegate: | SGL CARBON GmbH |
Contact: | Dr. Alfred Chodura |
Email: | alfred.chodura@sglgroup.com |
Website: | www.sglgroup.com |
Misc.
Method/Apparatus: | specific electric resistivity - current-voltage methode |
Ranges: | RT … 2000 |
Samples: | solids I: 110 thickness: 8-20 |
Institute/Delegate: | SGL Carbon GmbH |
Contact: | Dr. Marcus Franz Birgit Tartler |
Email: | Marcus.Franz@sglgroup.com Birgit.Tartler@sglgroup.com |
Website: | www.sglgroup.com |
Misc.
Method/Apparatus: | mechanical test - bending test, tensile test, compressive test |
Ranges: | RT … 1900 |
Samples: | solids |
Institute/Delegate: | SGL Carbon GmbH |
Contact: | Dr. Marcus Franz Birgit Tartler |
Email: | Marcus.Franz@sglgroup.com Birgit.Tartler@sglgroup.com |
Website: | www.sglgroup.com |
Misc.
Method/Apparatus: | STA; thermogravimetry TG +simultaneous DSC (DTA), FTIR, MS |
Ranges: | 40 … 1600or40 …1400 |
Samples: | solids, powders, pastes, liquids… |
Institute/Delegate: | thyssenkrupp Steel Europe AG |
Contact: | Dr. Diana Neubert |
Email: | diana.neubert@thyssenkrupp.com |
Website: | www.thyssenkrupp-steel.com |
Misc.
Method/Apparatus: | Seebeck coefficient and electrical conductivity |
Ranges: | RT … 1000 |
Samples: | solids |
Institute/Delegate: | Netzsch Gerätebau |
Contact: | Dr. André Lindemann |
Email: | andre.lindemann@netzsch.com |
Website: | www.netzsch.com |
Misc.
Method/Apparatus: | DSC-TG / STA (DTA-TG) and FTIR Tensor II |
Ranges: | RT … 1350 |
Samples: | solids, powders, pasts: 85µl, Ø<5mm, h<3mm; STA: 0,3ml..1,5ml |
Institute/Delegate: | IAB Institut für Angewandte Bauforschung Weimar gGmbH |
Contact: | Alexander Eppner |
Email: | a.eppner@iab-weimar.de |
Website: | www.iab-weimar.de |
Misc.
Method/Apparatus: | thermogravimetry TG +simultaneous DSC (DTA), FTIR, MS |
Ranges: | 30 … 1100 |
Samples: | solids, powders, pasts, melts, liquids, m: < 5g |
Institute/Delegate: | IKV an der RWTH Aachen |
Contact: | Dipl.-Ing. (FH) Michèle Marson-Pahle |
Email: | michele.marson-pahle@ikv.rwth-aachen.de |
Website: | www.ikv-aachen.de |
Misc.
Method/Apparatus: | DTA-TGA |
Ranges: | RT…1500 |
Samples: | solids, powders, liquidsm: 500 mg |
Institute/Delegate: | SCHOTT AG Mainz |
Contact: | Dr. Christoph Groß |
Email: | christoph1.gross@schott.com |
Website: | www.schott.com |
Viscosity
Method/Apparatus: | beam bending viscosimetry(e.g. Temp at 1013 dPas, 1013,2 dPas, 1014,7 dPas) |
Ranges: | 375…950 (1300) |
Samples: | solid piece:10x10x50 cm3 |
Institute/Delegate: | SCHOTT AG Mainz |
Contact: | Dr. Christoph Groß |
Email: | christoph1.gross@schott.com |
Website: | www.schott.com |
Viscosity
Method/Apparatus: | fibre elongation viscosimetry(e.g. Temp at 107,6 dPas) |
Ranges: | 300…1300 |
Samples: | solid piece:10x10x50 cm3 |
Institute/Delegate: | SCHOTT AG Mainz |
Contact: | Dr. Christoph Groß |
Email: | christoph1.gross@schott.com |
Website: | www.schott.com |
Viscosity
Method/Apparatus: | rotation viscosimetry(e.g. Temp at 104 dPas) |
Ranges: | 550…1650 (1750) |
Samples: | approx 100 cm3 |
Institute/Delegate: | SCHOTT AG Mainz |
Contact: | Dr. Christoph Groß |
Email: | christoph1.gross@schott.com |
Website: | www.schott.com |
Viscosity
Method/Apparatus: | viscosity curve(10-1 dPas - 1013,5 dPas) |
Ranges: | 375…1650 (1750) |
Samples: | as above |
Institute/Delegate: | SCHOTT AG Mainz |
Contact: | Dr. Christoph Groß |
Email: | christoph1.gross@schott.com |
Website: | www.schott.com |
Temp.dependenttransmis-sion
Method/Apparatus: | temperature dependence of UV-VIS-NIR transmission |
Ranges: | RT…1100 |
Samples: | solid pieceØ: 12 mm |
Institute/Delegate: | SCHOTT AG Mainz |
Contact: | Dr. RomeoDonfeu Tchana |
Email: | romeo1.donfeu@schott.com |
Website: | www.schott.com |
Thermo-optical-measurements
Method/Apparatus: | thermogravimetry, contact angle, shrinkage, adheasion, thermal shock, thermal cycling, creep, compression |
Ranges: | RT … 2200 |
Samples: | solids, powders, pastes, melts, fibers Ø: 6 .. 30h: 5 … 30 |
Institute/Delegate: | Fraunhofer ISC - Zentrum HTL |
Contact: | DI (FH) Jens Baber |
Email: | jens.baber@isc.fraunhofer.de |
Website: | www.htl.fraunhofer.de |
Specific heat
Method/Apparatus: | DSC - dynamic scanning calorimetry |
Ranges: | 100 … 1350 |
Samples: | solids, melts Ø: 4.9 I: 16 |
Institute/Delegate: | TU Bergakademie Freiberg |
Contact: | Dr. Rhena Wulf |
Email: | Rhena.Wulf@iwtt.tu-freiberg.de |
Website: | www.tu-freiberg.de |
Specific heat
Method/Apparatus: | DSC - dynamic scanning calorimetry |
Ranges: | -180 … 1600 |
Samples: | solids, powders, pastes, melts Ø: <5 h: ~ 1 |
Institute/Delegate: | Austrian Institute of Technology |
Contact: | DI (FH) Daniel Lager, MSc / Dr.-Ing.Wolfgang Hohenauer |
Email: | daniel.lager@ait.ac.at / wolfgang.hohenauer@ait.ac.at |
Website: | http://www.ait.ac.at/en/research-fields/thermophysics/ |
Specific heat
Method/Apparatus: | DSC - dynamic scanning calorimetry |
Ranges: | RT … 1500 |
Samples: | solids, melts, liquids Ø: < 5 h: < 1 |
Institute/Delegate: | ZAE Bayern |
Contact: | Michael Brütting |
Email: | michael.bruetting@zae-bayern.de |
Website: | www.zae-bayern.de |
Specific heat
Method/Apparatus: | DSC - dynamic scanning calorimetry |
Ranges: | -90 … 500 |
Samples: | solids, melts, liquids Ø: < 4.5 h: < 1 |
Institute/Delegate: | ZAE Bayern |
Contact: | Michael Brütting |
Email: | michael.bruetting@zae-bayern.de |
Website: | www.zae-bayern.de |
Specific heat
Method/Apparatus: | Macro - DSC |
Ranges: | 15 .. 50 |
Samples: | solids, melts, liquids < 100 x 100 h: < 20 |
Institute/Delegate: | ZAE Bayern |
Contact: | Michael Brütting |
Email: | michael.bruetting@zae-bayern.de |
Website: | www.zae-bayern.de |
Specific heat
Method/Apparatus: | DSC - dynamic scanning calorimetry |
Ranges: | RT … 1200 |
Samples: | solids, melts Ø: 6 thickness: 0.5 … 2 |
Institute/Delegate: | Österreichiches Gießerei-Institut |
Contact: | Dr. Erhard Kaschnitz |
Email: | erhard.kaschnitz@ogi.at |
Website: | www.ogi.at |
Specific heat
Method/Apparatus: | DSC 7 - pc dynamic scanning calorimetry |
Ranges: | -20 … 550 |
Samples: | solids, powders, melts, liquids, pastes Ø: 5 h: < 2 |
Institute/Delegate: | Fraunhofer IKTS Dresden |
Contact: | Dr. Tim Gestrich |
Email: | Tim.Gestrich@ikts.fraunhofer.de |
Website: | www.ikts.fraunhofer.de |
Specific heat
Method/Apparatus: | heat flow dynamic scanning calorimetry DSC 404, DSC 404C, DSC 404F1 |
Ranges: | -160 … 1600 |
Samples: | solids, powders, melts, liquids, pastes Ø: 5 h: < 2 |
Institute/Delegate: | Fraunhofer IKTS Dresden |
Contact: | Dr. Tim Gestrich |
Email: | Tim.Gestrich@ikts.fraunhofer.de |
Website: | www.ikts.fraunhofer.de |
Specific heat
Method/Apparatus: | DSC - dynamic scanning calorimetry |
Ranges: | 100 … 1450 |
Samples: | solids, melts, powders Ø: 5 thickness: 1 |
Institute/Delegate: | IWM RWTH Aachen |
Contact: | Tillmann Knoche/Renate Küppers |
Email: | t.knoche@iwm.rwth-aachen.de; r.kueppers@iwm.rwth-aachen.de |
Website: | www.iwm.rwth-aachen.de |
Specific heat
Method/Apparatus: | DSC - dynamic scanning calorimetry |
Ranges: | RT … 1500 |
Samples: | solids, melts, liquids Ø: < 5 thickness: < 1 |
Institute/Delegate: | Fraunhofer IPM |
Contact: | Jan König |
Email: | jan.koenig@ipm.fraunhofer.de |
Website: | www.ipm.fraunhofer.de |
Specific heat
Method/Apparatus: | DSC |
Ranges: | -45 … 90° |
Samples: | liquids, solids |
Institute/Delegate: | ILK Dresden gGmbH |
Contact: | Dr. Steffen Feja |
Email: | steffen.feja@ilkdresden.de |
Website: | www.ilkdresden.de |
Specific heat
Method/Apparatus: | DSC |
Ranges: | -180 … 750° |
Samples: | liquids, solids |
Institute/Delegate: | ILK Dresden gGmbH |
Contact: | Dr. Steffen Feja |
Email: | steffen.feja@ilkdresden.de |
Website: | www.ilkdresden.de |
Specific heat
Method/Apparatus: | µDSC VIIdynamic scanningcalorimetry |
Ranges: | -45…90 |
Samples: | liquids, solids |
Institute/Delegate: | ILK Dresden gGmbH |
Contact: | Dr. Steffen Feja |
Email: | steffen.feja@ilkdresden.de |
Website: | www.ilkdresden.de |
Specific heat
Method/Apparatus: | Q 200dynamic scanningcalorimetry |
Ranges: | -180…750 |
Samples: | liquids, solids |
Institute/Delegate: | ILK Dresden gGmbH |
Contact: | Dr. Steffen Feja |
Email: | steffen.feja@ilkdresden.de |
Website: | www.ilkdresden.de |
Specific heat
Method/Apparatus: | e.g. heat-pulse |
Ranges: | -265..50 |
Samples: | solidsapprox. 5 x 5 x 5 |
Institute/Delegate: | ILK Dresden gGmbH |
Contact: | Dr. MatthiasSchneider |
Email: | matthias.schneider@ilkdresden.d |
Website: | www.ilkdresden.de |
Specific heat
Method/Apparatus: | DSC - dynamic scanning calorimetry |
Ranges: | RT … 1600 |
Samples: | solids, powders, pastes, melts Ø: <5 h: < 2 |
Institute/Delegate: | Fraunhofer Institut für Werkstoffmechanik IWM |
Contact: | Dr. Dirk Helm |
Email: | dirk.helm@iwm.fraunhofer.de |
Website: | www.iwm.fraunhofer.de |
Specific heat
Method/Apparatus: | DSC - dynamic scanning calorimetry |
Ranges: | - 90 … 500 |
Samples: | solids, powders, pastes, melts |
Institute/Delegate: | SGL Carbon GmbH |
Contact: | Dr. Alfred Chodura |
Email: | alfred.chodura@sglgroup.com |
Website: | www.sglgroup.com |
Specific heat
Method/Apparatus: | STA; thermogravimetry TG +simultaneous DSC (DTA), FTIR, MS |
Ranges: | 40 … 1600 |
Samples: | solids, powders, pastes, liquids… |
Institute/Delegate: | thyssenkrupp Steel Europe AG |
Contact: | Dr. Diana Neubert |
Email: | diana.neubert@thyssenkrupp.com |
Website: | www.thyssenkrupp-steel.com |
Specific heat
Method/Apparatus: | DSC - dynamic scanning calorimetry |
Ranges: | /-120 … 1600 |
Samples: | solids, powders, pastes, melts Ø: <5 h: < 2 |
Institute/Delegate: | Netzsch Gerätebau |
Contact: | Dr. Jan Hanss |
Email: | jan.hanss@netzsch.com |
Website: | www.netzsch.com |
Specific heat
Method/Apparatus: | DSC Q2000 - dynamic scanning calorimetry |
Ranges: | -90 … 400 |
Samples: | solids, powders, pastes, melts, liquids Ø: <5 h: < 1 m: > 10 mg |
Institute/Delegate: | IKV an der RWTH Aachen |
Contact: | Dipl.-Ing. (FH) Michèle Marson-Pahle |
Email: | michele.marson-pahle@ikv.rwth-aachen.de |
Website: | www.ikv-aachen.de |
Specific heat
Method/Apparatus: | DSC - dynamic scanningcalorimetry |
Ranges: | 30…1000(1450) |
Samples: | solidsØ: 6h: 1,5 |
Institute/Delegate: | SCHOTT AG Mainz |
Contact: | Dr. Christoph Groß |
Email: | christoph1.gross@schott.com |
Website: | www.schott.com |
Specific heat
Method/Apparatus: | DSC Cp-measurements (DSC-404F3, 404C) |
Ranges: | RT … 1650 |
Samples: | solids Ø: <6 thickness: 0.5 … 2 |
Institute/Delegate: | FZ-Jülich- IEK-4-HML |
Contact: | Friedel Gormann Dr. Gerald Pintsuk |
Email: | f.gormann@fz-juelich.de g.pintsuk@fz-juelich.de |
Website: | 02461-61483902461-616383 |
Thermal conductivity
Method/Apparatus: | comparative stationary method |
Ranges: | RT … 500 |
Samples: | solids Ø: 25 h: 25 |
Institute/Delegate: | Österreichiches Gießerei-Institut |
Contact: | Dr. Erhard Kaschnitz |
Email: | erhard.kaschnitz@ogi.at |
Website: | www.ogi.at |
Thermal conductivity
Method/Apparatus: | TCT416 - thermal conductivity tester |
Ranges: | RT |
Samples: | solids/cross section 5 x 5 or Ø: 6 I: 25 (<5W/mK), 35 (>5W/mK) |
Institute/Delegate: | Fraunhofer IKTS Dresden |
Contact: | Dr. Tim Gestrich |
Email: | Tim.Gestrich@ikts.fraunhofer.de |
Website: | www.ikts.fraunhofer.de |
Thermal conductivity
Method/Apparatus: | comparative method |
Ranges: | 0 … 950 |
Samples: | solids, powders, pastes, Ø: 25, 50 h: ~ 10 … 30 |
Institute/Delegate: | IKEUniversität Stuttgart |
Contact: | Marc LinderDr. Rudi Kulenovic |
Email: | marc.linder@ike.uni-stuttgart.de /rudi.kulenovic@ike.uni-stuttgart.de |
Website: | www.ike.uni-stuttgart.de |
Thermal conductivity
Method/Apparatus: | guarded hot plate |
Ranges: | 0 … 650 |
Samples: | solids 2x Ø: 200 thickness: ~ 5 … 50 |
Institute/Delegate: | IKEUniversität Stuttgart |
Contact: | Marc LinderDr. Rudi Kulenovic |
Email: | marc.linder@ike.uni-stuttgart.de /rudi.kulenovic@ike.uni-stuttgart.de |
Website: | www.ike.uni-stuttgart.de |
Thermal conductivity
Method/Apparatus: | four-probe method |
Ranges: | RT … 1200 |
Samples: | metals (solid/molten) Ø: 5 I: 100 |
Institute/Delegate: | IKEUniversität Stuttgart |
Contact: | Marc LinderDr. Rudi Kulenovic |
Email: | marc.linder@ike.uni-stuttgart.de /rudi.kulenovic@ike.uni-stuttgart.de |
Website: | www.ike.uni-stuttgart.de |
Thermal conductivity
Method/Apparatus: | 3-omega method |
Ranges: | -90K … 600K |
Samples: | thin films and solids |
Institute/Delegate: | Fraunhofer IPM |
Contact: | Jan König |
Email: | jan.koenig@ipm.fraunhofer.de |
Website: | www.ipm.fraunhofer.de |
Thermal conductivity
Method/Apparatus: | TDTR method |
Ranges: | RT … 150 |
Samples: | thin films |
Institute/Delegate: | Fraunhofer IPM |
Contact: | Jan König |
Email: | jan.koenig@ipm.fraunhofer.de |
Website: | www.ipm.fraunhofer.de |
Thermal conductivity
Method/Apparatus: | stationary cylinder gap methode |
Ranges: | -40° … 90° |
Samples: | liquids |
Institute/Delegate: | ILK Dresden gGmbH |
Contact: | Dr. Steffen Feja |
Email: | steffen.feja@ilkdresden.de |
Website: | www.ilkdresden.de |
Thermal conductivity
Method/Apparatus: | ring-gap apparatus |
Ranges: | -40° … 80° |
Samples: | liquids50 ml |
Institute/Delegate: | ILK Dresden gGmbH |
Contact: | Dr. Steffen Feja |
Email: | steffen.feja@ilkdresden.de |
Website: | www.ilkdresden.de |
Thermal conductivity
Method/Apparatus: | two-plate method |
Ranges: | -265 … 50 |
Samples: | solidsØ60 x 5or similar |
Institute/Delegate: | ILK Dresden gGmbH |
Contact: | Dr. Matthias Schneider |
Email: | matthias.schneider@ilkdresden.de |
Website: | www.ilkdresden.de |
Thermal conductivity
Method/Apparatus: | transient hot bridge |
Ranges: | -15 … 200 |
Samples: | solids in various dimensions, powders, pastes, melts, liquids |
Institute/Delegate: | AIT Austrian Institute of Technoglogy |
Contact: | DI (FH) Daniel Lager, MSc / Dr.-Ing.Wolfgang Hohenauer |
Email: | daniel.lager@ait.ac.at / wolfgang.hohenauer@ait.ac.at |
Website: | http://www.ait.ac.at/en/research-fields/thermophysics/ |
Thermal conductivity
Method/Apparatus: | heat flow meter |
Ranges: | -20 … 90 |
Samples: | solids 200x200x50 mm; powders (V=0.6 dm³) |
Institute/Delegate: | AIT Austrian Institute of Technoglogy |
Contact: | DI (FH) Daniel Lager, MSc / Dr.-Ing.Wolfgang Hohenauer |
Email: | daniel.lager@ait.ac.at / wolfgang.hohenauer@ait.ac.at |
Website: | http://www.ait.ac.at/en/research-fields/thermophysics/ |
Thermal conductivity
Method/Apparatus: | comparative method |
Ranges: | RT |
Samples: | solids Ø: 30 oder 20 |
Institute/Delegate: | SGL Carbon GmbH |
Contact: | Dr. Christian Stang, Thomas Rusch |
Email: | Christian.Stang@sglgroup.com Thomas.Rusch@sglgroup.com |
Website: | www.sglgroup.com |
Thermal conductivity
Method/Apparatus: | guarded hot plate |
Ranges: | -160 … 600 |
Samples: | insulation material 300 mm x 300 mm thickness up to 100 mm |
Institute/Delegate: | Netzsch Gerätebau GmbH |
Contact: | Fabia Beckstein |
Email: | fabia.beckstein@netzsch.com |
Website: | www.netzsch-thermal-analysis.com |
Thermal conductivity
Method/Apparatus: | heat flow meter |
Ranges: | 10 … 90 |
Samples: | insulation material, building material 300 mm x 300 mm thickness up to 100 mm |
Institute/Delegate: | Netzsch Gerätebau GmbH |
Contact: | Fabia Beckstein |
Email: | fabia.beckstein@netzsch.com |
Website: | www.netzsch-thermal-analysis.com |
Thermal conductivity
Method/Apparatus: | heat flow meter |
Ranges: | -20 … 80 |
Samples: | insulation material 300 mm x 300 mm thickness up to 100 mm |
Institute/Delegate: | Netzsch Gerätebau GmbH |
Contact: | Fabia Beckstein |
Email: | fabia.beckstein@netzsch.com |
Website: | www.netzsch-thermal-analysis.com |
Thermal conductivity
Method/Apparatus: | heat flow meter |
Ranges: | -10 … 80 |
Samples: | insulation material, building material 200 mm x 200 mm thickness up to 50 mm |
Institute/Delegate: | Netzsch Gerätebau GmbH |
Contact: | Fabia Beckstein |
Email: | fabia.beckstein@netzsch.com |
Website: | www.netzsch-thermal-analysis.com |
Thermal conductivity
Method/Apparatus: | laser flash |
Ranges: | -100 … 500 |
Samples: | solids 12.6 mm diameter < 3 mm |
Institute/Delegate: | Netzsch Gerätebau GmbH |
Contact: | Fabia Beckstein |
Email: | fabia.beckstein@netzsch.com |
Website: | www.netzsch-thermal-analysis.com |
Thermal conductivity
Method/Apparatus: | laser flash |
Ranges: | RT … 2000°C |
Samples: | solids 12.6 mm diameter thickness < 3 mm |
Institute/Delegate: | Netzsch Gerätebau GmbH |
Contact: | Dr.-Ing. André Lindemann |
Email: | andre.lindemann@netzsch.com |
Website: | www.netzsch-thermal-analysis.com |
Thermal conductivity
Method/Apparatus: | thermoreflectance |
Ranges: | RT |
Samples: | thin films 10 mm x 10 mm thickness: 10 ….10000 nm |
Institute/Delegate: | Netzsch Gerätebau GmbH |
Contact: | Dr.-Ing. André Lindemann |
Email: | andre.lindemann@netzsch.com |
Website: | www.netzsch-thermal-analysis.com |
Thermal conductivity
Method/Apparatus: | Transient plane heat source (hot disc) method |
Ranges: | RT … 170 (750) |
Samples: | solids in various dimensions, powders, liquids |
Institute/Delegate: | IKV an der RWTH Aachen |
Contact: | Dipl.-Ing. (FH) Michèle Marson-Pahle |
Email: | michele.marson-pahle@ikv.rwth-aachen.de |
Website: | www.ikv-aachen.de |
Thermal conductivity
Method/Apparatus: | guarded hot plate |
Ranges: | 0 … 120 |
Samples: | solids 100 x 100 thickness: 4 bis 15 |
Institute/Delegate: | IKV an der RWTH Aachen |
Contact: | Dipl.-Ing. (FH) Michèle Marson-Pahle |
Email: | michele.marson-pahle@ikv.rwth-aachen.de |
Website: | www.ikv-aachen.de |
Thermal conductivity
Method/Apparatus: | Transient Line-Source Technique |
Ranges: | 30 … 280 |
Samples: | from melt to solid, pastes |
Institute/Delegate: | IKV an der RWTH Aachen |
Contact: | Dipl.-Ing. (FH) Michèle Marson-Pahle |
Email: | michele.marson-pahle@ikv.rwth-aachen.de |
Website: | www.ikv-aachen.de |
Thermalconductivity
Method/Apparatus: | transient plane source |
Ranges: | RT-300 |
Samples: | solids Ø: > 10..50 I: > 10..50 |
Institute/Delegate: | Fraunhofer ISC - Zentrum HTL |
Contact: | DI (FH) Jens Baber |
Email: | jens.baber@isc.fraunhofer.de |
Website: | www.htl.fraunhofer.de |
Thermal diffusivity
Method/Apparatus: | laser flash |
Ranges: | 25 … 1600 |
Samples: | solids, melts Ø: 12.6 thickness: 1 … 6 |
Institute/Delegate: | TU Bergakademie Freiberg |
Contact: | Dr. Rhena Wulf |
Email: | Rhena.Wulf@iwtt.tu-freiberg.de |
Website: | www.tu-freiberg.de |
Thermal diffusivity
Method/Apparatus: | laser flash |
Ranges: | -250 … 2800 |
Samples: | solids, foils, melts Ø: 12.7, var. 5 .. 25.4, 10 x 10 thickness: 0.1 .. 6 |
Institute/Delegate: | ZAE Bayern |
Contact: | Michael Brüttimg |
Email: | michael.bruetting@zae-bayern.de |
Website: | www.zae-bayern.de |
Thermal diffusivity
Method/Apparatus: | laser flash |
Ranges: | RT … 1500 |
Samples: | solids, melts Ø: 12.6 thickness: 2 … 5 |
Institute/Delegate: | Österreichiches Gießerei-Institut |
Contact: | Dr. Erhard Kaschnitz |
Email: | erhard.kaschnitz@ogi.at |
Website: | www.ogi.at |
Thermal diffusivity
Method/Apparatus: | laser flash |
Ranges: | RT … 1200 |
Samples: | solids Ø: 20 thickness: 2 … 5 |
Institute/Delegate: | RHI AG TC-Leoben |
Contact: | Alois Triessnig Gerhard Urbanek |
Email: | alois.triessnig@rhi-ag.com /gerhard.urbanek@rhi-ag.com |
Website: | www.rhi-ag.com |
Thermal diffusivity
Method/Apparatus: | laser flash |
Ranges: | 10°C … 1500 |
Samples: | solids, powders, melts liquids, pastes Ø: 6 … 25 h: 0.1 … 8 |
Institute/Delegate: | Fraunhofer IKTS Dresden |
Contact: | Dr. Tim Gestrich |
Email: | Tim.Gestrich@ikts.fraunhofer.de |
Website: | www.ikts.fraunhofer.de |
Thermal diffusivity
Method/Apparatus: | laser flash |
Ranges: | RT … 2000 |
Samples: | solids, powders, melts Ø: 12.7 thickness: 1 … 6 |
Institute/Delegate: | IWM RWTH Aachen |
Contact: | Tillmann Knoche/Renate Küppers |
Email: | t.knoche@iwm.rwth-aachen.de; r.kueppers@iwm.rwth-aachen.de |
Website: | www.iwm.rwth-aachen.de |
Thermal diffusivity
Method/Apparatus: | laser flash |
Ranges: | -190 … 1500 |
Samples: | Ø: 12.5 thickness: ~ 1.5 |
Institute/Delegate: | Fraunhofer IPM |
Contact: | Jan König |
Email: | jan.koenig@ipm.fraunhofer.de |
Website: | www.ipm.fraunhofer.de |
Thermal diffusivity
Method/Apparatus: | laser flash |
Ranges: | RT … 2000 |
Samples: | solids, powders, pastes, melts Ø: 6, 10, 12.7, 10 x 10 h: 0.1 … 10 |
Institute/Delegate: | Fraunhofer Institut für Werkstoffmechanik IWM |
Contact: | Dr. Dirk Helm |
Email: | dirk.helm@ iwm.fraunhofer.de |
Website: | www.iwm.fraunhofer.de |
Thermal diffusivity
Method/Apparatus: | ring-gap apparatus |
Ranges: | -40 … 80 |
Samples: | liquids 50 ml |
Institute/Delegate: | ILK Dresden gGmbH |
Contact: | Dr. Steffen Feja |
Email: | steffen.feja@ilkdresden.de |
Website: | www.ilk-dresden.de |
Thermal diffusivity
Method/Apparatus: | laser flash |
Ranges: | -150 … 1600 |
Samples: | solids in various dimensions (6-25,4 mm), powders, liquids, pastes, melts |
Institute/Delegate: | AIT Autrian Institute of Technology |
Contact: | DI (FH) Daniel Lager MSc / Dr.-Ing. Wolfgang Hohenauer |
Email: | daniel.lager@ait.ac.at / wolfgang.hohenauer@ait.ac.at |
Website: | http://www.ait.ac.at/en/research-fields/thermophysics/ |
Thermal diffusivity
Method/Apparatus: | laser flash |
Ranges: | RT … 2000 |
Samples: | solids, powders, melts Ø: 20 thickness: 3 … 10 |
Institute/Delegate: | SGL Carbon GmbH |
Contact: | Dr. Marcus Franz Birgit Tartler |
Email: | Marcus.Franz@sglgroup.com Birgit.Tartler@sglgroup.com |
Website: | www.sglgroup.com |
Thermal diffusivity
Method/Apparatus: | laser flash |
Ranges: | -100 … 500 |
Samples: | solids 12.6 mm diameter < 3 mm |
Institute/Delegate: | Netzsch Gerätebau GmbH |
Contact: | Fabia Beckstein |
Email: | fabia.beckstein@netzsch.com |
Website: | www.netzsch-thermal-analysis.com |
Thermal diffusivity
Method/Apparatus: | laser flash |
Ranges: | RT … 2000°C |
Samples: | solids 12.6 mm diameter thickness < 3 mm |
Institute/Delegate: | Netzsch Gerätebau GmbH |
Contact: | Dr.-Ing. André Lindemann |
Email: | andre.lindemann@netzsch.com |
Website: | www.netzsch-thermal-analysis.com |
Thermal diffusivity
Method/Apparatus: | thermoreflectance |
Ranges: | RT |
Samples: | thin films 10 mm x 10 mm thickness: 10 ….10000 nm |
Institute/Delegate: | Netzsch Gerätebau GmbH |
Contact: | Dr.-Ing. André Lindemann |
Email: | andre.lindemann@netzsch.com |
Website: | www.netzsch-thermal-analysis.com |
Thermal diffusivity
Method/Apparatus: | laser flash |
Ranges: | RT … 500 |
Samples: | solids in various dimensions, powders, pasts melts, liquids |
Institute/Delegate: | IKV an der RWTH Aachen |
Contact: | Dipl.-Ing. (FH) Michèle Marson-Pahle |
Email: | michele.marson-pahle@ikv.rwth-aachen.de |
Website: | www.ikv-aachen.de |
Thermal diffusivity
Method/Apparatus: | laser flash |
Ranges: | RT…2800 |
Samples: | solids in various dimensions |
Institute/Delegate: | FZ-Jülich-IEK-4-HML |
Contact: | Friedel Gormann Dr. Gerald Pintsuk |
Email: | f.gormann@fz-juelich.de g.pintsuk@fz-juelich.de |
Website: | 02461-614839 02461-616383 |